Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jul 3;7(2):7053.
doi: 10.4081/ijfs.2018.7053.

Noise assessment in slaughterhouses by means of a smartphone app

Affiliations

Noise assessment in slaughterhouses by means of a smartphone app

Maria Francesca Iulietto et al. Ital J Food Saf. .

Abstract

Regulation (EC) No. 1099/2009 on the protection of animals at the time of killing establishes an obligation to spare animals any avoidable suffering or stress prior to their slaughter. Although it has been pointed out that stressors also include noise, which can cause suffering and affect the quality of the meat, current legislation does not set a limit for environmental noise in slaughterhouses. This study was conducted in three slaughterhouses in central Italy to assess the environmental acoustic level using a smartphone app. The selected, medium-sized slaughterhouses for pigs and cattle were subjected to measurements using a sound-level meter (Noise Meter for iOS) during working hours at the unloading area and lairage, along the chute to the restraining pen, at the time of stunning and at the slaughter hall. For the bovine lines the average values expressed in dB ranged from 76.33 (SD 2.08) to 93.00 (SD 2.14) for abattoir 1, from 75.00 (SD 1.87) to 92.33 (SD 4.89) for abattoir 2 and from 75.67 (SD 7.09) to 88.83 (SD 4.79) for abattoir 3. For the pig lines the average values expressed in dB ranged from 77.50 (SD 3.11) to 100.33 (SD 1.53) for abattoir 1, from 83.00 (SD 2.00) to 99.75 (SD 2.63) for abattoir 2 and from 71.20 (SD 6.49) to 99.50 (SD 1.31) for abattoir 3. Data show that the pig slaughter line was always noisier than the cattle line and the slaughter hall always showed the highest values (i.e. 100 dB), when compared to the unloading area (i.e. 79 dB).

Keywords: Abattoir; Animal protection; Decibel; Noise assessment.

PubMed Disclaimer

Conflict of interest statement

Conflict of interests: the authors declare no potential conflict of interests.

References

    1. Anonymous, 2009. Council regulation ec no 1099/2009 of 24 september 2009 on the protection of animals at the time of killing.
    1. Berg C, 2012. Monitoring animal welfare at slaughterhouses. Sustainable agriculture; Uppsala: p. 349-351.
    1. Brouček J, 2014. Effect of noise on performance, stress and behavior of animals Slovak J Anim Sci 47:111-23.
    1. Coppola CL, Enns RM, Grandin T, 2006. Noise in the animal shelter environment: Building design and the effects of daily noise exposure. J Appl Anim Welfare Sci 9:1-7. - PubMed
    1. Goumon S, Faucinato L, 2017. Influence of loading handling and facilities on the subsequent response to pre-slaughter stress in pigs. Livestock Sci 200:6-13.