[HCL] APC Back-UPS BE1050G2 supported by usbhid-ups #3025
Copy link
Copy link
Open
Labels
APCDDLHCLUSBimpacts-release-2.8.0Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)
Description
APC Back-UPS BE1050G2
lusboutput:
Bus 001 Device 007: ID 051d:0002 American Power Conversion Uninterruptible Power Supply
upscoutput:
Init SSL without certificate database
battery.charge: 97
battery.charge.low: 10
battery.mfr.date: 2001/01/01
battery.runtime: 3833
battery.runtime.low: 120
battery.type: PbAc
battery.voltage: 13.7
battery.voltage.nominal: 12.0
device.mfr: American Power Conversion
device.model: Back-UPS BE1050G2
device.serial: 9B2436A02276
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: auto
driver.version: 2.8.0
driver.version.data: APC HID 0.98
driver.version.internal: 0.47
driver.version.usb: libusb-1.0.26 (API: 0x1000109)
input.sensitivity: medium
input.transfer.high: 266
input.transfer.low: 180
input.voltage: 245.0
input.voltage.nominal: 230
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.firmware: 497200G -497300G
ups.load: 0
ups.mfr: American Power Conversion
ups.mfr.date: 2024/09/10
ups.model: Back-UPS BE1050G2
ups.productid: 0002
ups.realpower.nominal: 600
ups.serial: 9B2436A02276
ups.status: OL CHRG
ups.test.result: Done and passed
ups.timer.reboot: 0
ups.timer.shutdown: -1
ups.vendorid: 051d
upsrwoutput:
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 10
Value: 10
[battery.mfr.date]
Battery manufacturing date
Type: STRING
Maximum length: 10
Value: 2001/01/01
[battery.runtime.low]
Remaining battery runtime when UPS switches to LB (seconds)
Type: STRING
Maximum length: 10
Value: 120
[input.sensitivity]
Input power sensitivity
Type: STRING
Maximum length: 10
Value: medium
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 266
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 180
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
upscmdoutput:
Instant commands supported on UPS [ups]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
test.panel.start - Start testing the UPS panel
test.panel.stop - Stop a UPS panel test
- Shutdown sequence tested & confirmed working.
The UPS is available in multiple VA & plug configurations, but the internals looks to be the same (based on the "User Manual" on Schneider's site) , I've only tested the "GR" version with Schuko plugs.
I can't seem to find an english product page from Schneider, but here is to the Norwegian one if you want to look it up:
https://www.se.com/no/no/product/BE1050G2-GR/apc-backups-1050va-600w-gulv-veggmontert-230v-8x-cee-7-3-schukouttak-usb-type-a+cport-brukerutskiftbart-batteri/
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
APCDDLHCLUSBimpacts-release-2.8.0Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)
Type
Projects
- StatusShow more project fieldsTodo
Activity
jimklimov commentedon Jul 20, 2025
Thanks!